The maximum clock frequency of the SN74AC374DWRE4 is 100 MHz, but this can vary depending on the operating conditions and the quality of the clock signal.
-
To ensure proper initialization, connect the Master Reset (MR) input to a pull-up resistor and a capacitor to VCC. This will ensure that the flip-flops are reset on power-up and then release the reset when the capacitor is fully charged.
-
The recommended termination scheme for the outputs of the SN74AC374DWRE4 is to use a 33-ohm series resistor and a 47-pF capacitor to VCC or GND, depending on the output loading and signal integrity requirements.
-
Yes, the SN74AC374DWRE4 can be used in a 3.3V system, but the input voltage thresholds and output voltage levels will be different from those specified in the datasheet. Consult the datasheet for specific details on 3.3V operation.
-
In a synchronous design, the asynchronous reset input (MR) should be synchronized with the clock signal using a flip-flop or a synchronizer circuit to avoid metastability issues.